Karakteristik Disturbansi di Rentang Frekuensi 9-150 kHz Pada Sistem UPS Berbeban Induktif

Rheo Loridho Pratama, Budi Sudiarto

Abstract


In every UPS device there are power electronic components including inverters, therefore using an inverter will cause voltage disturbances at high frequency because the switching frequency of the inverter is at high frequency. Data recorded by the oscilloscope along with the Picolog Recorder software and processed by  Matlab software to make it more efficient. Research conducted when the UPS uses dual conversion mode and with inductive load variations 0.35 H, 0.7 H, 1.4 H and 2.8 H. The test results show that voltage disturbances occur in three dominant frequency ranges at each level of load variations are 9-19 kHz, 20-30 kHz and 31-41 kHz. In the condition of 10% loading rate with a load of 0.35 H the peak voltage disturbances occur at 81.17 mV in frequency of 9.2 kHz and at the condition of the 75% loading rate with 2.8 H load the peak voltage disturbances that occur at 92.20 mV in frequency of 9.6 kHz. The disturbances voltage increases with the increasing of  inductive loads that connected to UPS.


Keywords


inverter; UPS; disturbances; frequency

Full Text:

PDF

References


Alqinsi, A., Edward, I. J. M., Ismail, N., & Darmalaksana, W. (2018). IoT-Based UPS Monitoring System Using MQTT Protocols. 1–5.

Anne, G., Jan, M., & Sarah, R. (2018). Comparison of Measurement Methods for the Frequency Range 2 – 150 kHz (Supraharmonics). 1–6.

Liu, X., Teng, D., Wang, D., Zhu, Q., & Liu, Z. (2017). Application of eco Mode UPS in data center. 30–34.

Muhammad, N. (2019). Analisa Karakteristik Disturbansi Frekuensi 9 – 150 kHz pada Sistem Photovoltaic Terhadap Variasi Tipe Beban dan Pemberian Efek Bayang-Bayang [Tesis]. Universitas Indonesia.

Ohn, S., Yu, J., Rankin, P., Sun, B., Burgos, R., Boroyevich, D., Suryanarayana, H., & Belcastro, C. (2019). Three-Terminal Common-Mode EMI Model for EMI Generation, Propagation, and Mitigation in a Full-SiC Three-Phase UPS Module. 34, 8599–8612.

Pasini, G., Peretto, L., & Ariatta, A. (2012). Method and measurement set up for the evaluation of the performance of UPS in presence of network outages. 1–5.

Purnamaputra, R., & Sudiarto, B. (2019). Disturbance Frequency 9 – 150 kHz Characteristics towards Total Demand Distortion on On-Grid Solar Panel System in the Electrical System of Kuningan Gas Station. 1–6.

Sudiarto, B. (2017). The Properties and Behavior of Disturbances in the Frequency Range 9 kHz to 150 kHz Produced by Household Appliances in a Residential Network Environment [Disertasi Doktor]. Universität Duisburg-Essen.




DOI: http://dx.doi.org/10.22373/crc.v4i1.6276

Refbacks

  • There are currently no refbacks.


Copyright (c) 2020 CIRCUIT: Jurnal Ilmiah Pendidikan Teknik Elektro



               

 

Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro
P-ISSN 2549-3698
E-ISSN 2549-3701
Published by Electrical and Engineering Education Department, Tarbiyah and Teaching Learning Faculty, Universitas Islam Negeri Ar-Raniry, Banda Aceh, Indonesia
Email: jurnal.circuit@ar-raniry.ac.id

Creative Commons License
Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.